Arq. bras. oftalmol ; 77(6): 382-387, Nov-Dec/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-735805

RESUMO

Purpose: To describe quantitative and qualitative features of eyes with advanced bullous keratopathy assessed using ultrasound biomicroscopy, before and after anterior stromal puncture (ASP) or amniotic membrane transplantation (AMT) procedures to relieve chronic pain. Methods: The present descriptive comparative study included 40 eyes of 40 patients with chronic intermittent pain due to bullous keratopathy who were randomly assigned to one of the two treatments (AMT or ASP). Ultrasound biomicroscopy (Humphrey, UBM 840, 50 MHz transducer, immersion technique) was used, and a questionnaire about pain intensity was completed preoperatively and postoperatively at days 90 and 180, respectively. Exclusion criteria were age<18 years, presence of concurrent infection, ocular hypertension, and absence of pain. Results: In a 180-day follow-up, the AMT group exhibited mean central corneal thickness (CCT), 899.4 µm preoperatively and 1122.5 µm postoperatively (p<0.001); mean epithelial thickness (ET), 156.4 µm preoperatively and 247.8 µm postoperatively (p<0.001); and mean stromal thickness (ST), 742.9 µm preoperatively and 826.3 µm postoperatively (p=0.005). The ASP group exhibited mean CCT, 756.7 µm preoperatively and 914.8 µm postoperatively (p<0.001); mean ET, 102.1 µm preoperatively and 245.2 µm postoperatively (p<0.001); and mean ST, 654.6 µm preoperatively and 681.5 µm postoperatively (p<0.999). Correlations between CCT and pain intensity in the AMT group (p=0.209 pre- and postoperatively) and the ASP group (p=0.157 preoperatively and p=0.426 at the 180-day follow-up) were not statistically significant. Epithelial and stromal edema, Descemet’s membrane folds, epithelial bullae, and the presence of interface fluid were frequently observed qualitative features. Conclusion: CCT increased over time in both groups. The magnitude of CCT did not correlate with pain intensity in the sample studied. The presence of interface ...


Objetivo: Descrever as características quantitativas e qualitativas da biomicroscopia ultrassônica (UBM) em olhos com ceratopatia bolhosa avançada, antes e após os procedimentos de punção estromal anterior (ASP) ou transplante de membrana amniótica (AMT) para alívio de dor crônica. Métodos: Estudo comparativo descritivo incluindo 40 olhos de 40 pacientes com dor crônica intermitente devido a ceratopatia bolhosa, randomizados em duas modalidades de tratamento (AMT e ASP). Biomicroscopia ultrassônica (Humphrey, UBM 840, transdutor de 50 MHz, técnica de imersão) foi utilizada, e um questionário de avaliação da intensidade da dor foi aplicado no pré-operatório, e após 90 e 180 dias de pós-operatório. Critérios de exclusão foram: idade abaixo de 18 anos, presença de infecção, hipertensão ocular, e ausência de dor. Resultados: No seguimento de 180 dias, o grupo Transplante de membrana amniótica apresentou: média da espessura corneana central (CCT): 899,4 µm (pré), 1.122,5 µm (pós-operatório) (p<0,001); média da espessura epitelial (ET): 156,4 µm (pré), 247,8 µm (pós-operatório) (p<0,001); média da espessura estromal (ST): 742,9 µm (pré), 826,3 µm (pós-operatório) (p=0,005), e, grupo ASP apresentou: CCT média: 756.7 µm (pré), 914,8µm (pós-operatório) (p<0,001); ET média: 102,1 µm (pré), 245,2 µm (pós-operatório) (p<0,001); ST média: 654,6 µm (pré), 681.5 µm (pós-operatório) (p<0,999). A correlação entre intensidade da dor e espessura corneana central no grupo AMT (p=0,209 pré e pós-operatórios) e no grupo ASP (p=0,157 pré-operatório e p=0,426 aos 180 dias de seguimento) não foi significativa. Edema epitelial e estromal, dobras na membrana de Descemet, bolhas epiteliais, e presença de fluido na interface foram características qualitativas frequentemente observadas. Conclusão: A espessura corneana central aumentou ao longo do tempo em ambos os grupos. A magnitude da espessura corneana central não interfere na intensidade da dor ...


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Doenças da Córnea/cirurgia , Doenças da Córnea , Âmnio/transplante , Vesícula/cirurgia , Paquimetria Corneana , Substância Própria/patologia , Substância Própria/cirurgia , Substância Própria , Endotélio Corneano/patologia , Endotélio Corneano/cirurgia , Endotélio Corneano , Dor Ocular/cirurgia , Microscopia Acústica/métodos , Medição da Dor , Período Pós-Operatório , Período Pré-Operatório , Punções , Manejo da Dor/métodos , Cuidados Paliativos/métodos , Estatísticas não Paramétricas , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
2.
Arq. bras. oftalmol ; 76(6): 374-376, nov.-dez. 2013. ilus
Artigo em Português | LILACS | ID: lil-701291

RESUMO

Estabelecer padrão evolutivo de um caso de esclerite nodular à ultrassonografia de alta frequência durante o tratamento. Mulher, 27 anos, com manifestação inicial de uveíte intermediária, edema macular bilateral após tratamento clínico com corticosteroide tópico e via oral. Após quatro meses, observou-se a formação de um nódulo escleral no olho direito quando foi submetido à ultrassonografia de alta frequência (Paradigm, transdutor de 50 MHz, técnica de imersão). A lesão do olho direito foi caracterizada à ultrassonografia de alta frequência como uma lesão nodular da parede anterior temporal inferior associada à redução localizada da espessura da escleral. Após a injeção intravítrea de triancinolona para tratamento do edema macular, observou-se a regressão clínica do nódulo escleral no olho direito, mantendo reduzida a espessura escleral. A ultrassonografia de alta frequência auxiliou no diagnóstico da esclerite nodular durante as fases de tratamento e na identificação da sua sequela característica, o afinamento escleral.


To stablish evolutionary pattern of a case of nodular scleritis with high frequency ultrasound during treatment. Twenty-seven year old female, initial manifestation of intermediate uveitis, bilateral macular edema after clinical treatment with topical and oral steroids. After four months, we observed the formation of a scleral nodule in the right eye when patient underwent high frequency ultrasound (Paradigm, 50 MHz transducer, immersion technique). The lesion in right eye was characterized at high frequency ultrasound as a nodular lesion located at the anterior inferior temporal wall associated with localized reduction of scleral thickness. After intravitreal injection of triamcinolone for treatment of macular edema, clinical regression of the scleral nodule was observed in right eye, maintaining reduced scleral thickness. High frequency ultrasound assisted in the diagnosis of nodular scleritis during the phases of treatment and in the identify its characteristic sequel feature, the scleral thinning.


Assuntos
Adulto , Feminino , Humanos , Microscopia Acústica/métodos , Esclerite , Progressão da Doença , Glucocorticoides/uso terapêutico , Injeções Intravítreas , Edema Macular/tratamento farmacológico , Edema Macular , Esclerite/tratamento farmacológico , Resultado do Tratamento , Triancinolona/uso terapêutico , Uveíte Intermediária/tratamento farmacológico , Uveíte Intermediária
3.
Arq. bras. oftalmol ; 76(3): 147-151, maio-jun. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-681845

RESUMO

OBJETIVOS: Avaliar a posição das alças das lentes intraoculares implantadas intencionalmente no sulco ciliar, em olhos submetidos à cirurgia de catarata com complicação de ruptura de cápsula posterior, e correlacionar os achados com alterações clínicas observadas no exame oftalmológico, utilizando a biomicroscopia ultrassônica. MÉTODOS: Onze olhos (11 pacientes) que apresentaram ruptura de cápsula posterior durante a cirurgia de catarata com implantação intencional das alças no sulco ciliar foram submetidos ao exame oftalmológico e biomicroscopia ultrassônica. Biomicroscopia ultrassônica avaliou os seguintes parâmetros: posicionamento da porção distal das alças, inclinação e descentração da lente intraocular. O exame oftalmológico foi focalizado para avaliar a presença de "flare" e células na câmara anterior, depósitos na lente e defeitos de transiluminação de íris. A pressão intraocular foi medida, a pigmentação do trabeculado foi determinada, e a avaliação fundoscópica foi necessária para afastar a presença de ruptura retiniana periférica e edema de mácula. RESULTADOS: Tempo pós-operatório médio para os exames: 103,09 ± 32,93 dias. Assimetria da posição foi observada em 3 olhos (27,2%), que tinham alça no sulco ciliar e a segunda alça localizada na pars plana em 2 olhos, associada à inclinação e descentração da lente intraocular; ou no corpo ciliar (1 olho). O exame oftalmológico observou: 5 (45,5%) olhos com defeitos de transiluminação de íris, 2 (18,1%) olhos com descentração da lente intraocular; 1 olho (9%) apresentou hipertensão intraocular. Em todos os casos observou-se hiperpigmentação do trabeculado à gonioscopia. Nenhum caso de rotura periférica de retina e/ou edema de mácula foi relatado. CONCLUSÕES: A biomicroscopia ultrassônica foi capaz de localizar as alças das lentes intraoculares implantadas intencionalmente no sulco ciliar durante cirurgia complicada de catarata, e pôde demonstrar a relação da descentração da lente intraocular com a implantação assimétrica das alças.


PURPOSE: To evaluate the position of haptics of intraocular lens intentionally implanted in the ciliary sulcus in eyes undergoing cataract surgery complication associated with intraoperative posterior capsule rupture, as well as to correlate the findings with clinical changes observed in ophthalmic examination, utilizing ultrasound biomicroscopy. METHODS: Eleven eyes (11 patients) who had posterior capsule rupture during cataract surgery with intentional implantation of the haptics in the ciliary sulcus, underwent complete ophthalmic examination and ultrasound biomicroscopy. Ultrasound biomicroscopy evaluated the parameters: positioning of the distal portion of the haptics, tilt and decentration of the intraocular lens. Ophthalmic examination was aimed to evaluate the presence of flare and cells in the anterior chamber, deposits on the lens and iris transillumination defects. Intraocular pressure was measured, pigmentation of the trabecular meshwork was determined, and a fundoscopic evaluation was needed to rule out peripheral retinal rupture and macular edema. RESULTS: Mean postoperative time for the examinations: 103.09 ± 32.93 days. Asymmetry of the haptics positioning was observed in 3 eyes (27.2%) that had one haptic in the ciliary sulcus, the second haptic was placed in the pars plana in 2 eyes, associated to intraocular lens tilt and decentration; or in the ciliary body (1 eye). Ophthalmic examination observed: 5 (45.5%) eyes with iris transillumination defects, 2 (18.1%) with intraocular lens decentration; 1 eye (9%) presented ocular hypertension. In all cases trabecular hyperpigmentation was observed at gonioscopy. No cases of peripheral retinal rupture and/or macular edema were reported. CONCLUSIONS: Ultrasound biomicroscopy was able to locate the intraocular lens haptics intentionally implanted in the ciliary sulcus during complicated cataract surgery, and could demonstrate the relation of intraocular lens decentration to assymetric haptic implantation.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Corpo Ciliar/cirurgia , Lentes Intraoculares , Implante de Lente Intraocular/métodos , Microscopia Acústica/métodos , Facoemulsificação/métodos , Gonioscopia , Facoemulsificação/efeitos adversos , Ruptura da Cápsula Posterior do Olho/etiologia , Valores de Referência , Tonometria Ocular , Resultado do Tratamento
4.
Arq. bras. oftalmol ; 75(2): 122-125, mar.-abr. 2012. ilus, graf
Artigo em Português | LILACS | ID: lil-640159

RESUMO

INTRODUÇÃO: O traumatismo ocular é a causa mais importante de perda visual no mundo, sendo um problema de saúde pública. Os corpos estranhos intraoculares são relacionados a atividades que envolvem manuseio de objetos metálicos, porém outros materiais podem estar presentes, e devem ser diagnosticados e localizados no olho. A ultrassonografia biomicroscópica é uma ferramenta complementar adequada para avaliar um corpo estranho do segmento anterior do olho. OBJETIVO: Caracterizar a natureza, localização, dimensões de corpos estranhos e lesões associadas ao segmento anterior, utilizando-se ultrassonografia biomicroscópica. MÉTODO: Estudo clínico retrospectivo, por meio da análise de 7.182 prontuários dos anos de 1999 a 2008, com 59 exames de pacientes com suspeita de corpo estranho no segmento anterior ocular. RESULTADOS: Dentre os 59 exames, confirmou-se pela ultrassonografia biomicroscópica a presença de corpo estranho no segmento anterior em 42 (71,19%) olhos de 42 pacientes. A idade dos pacientes variou entre 9 e 76 anos (média= 37,4 anos). Houve predominância do sexo masculino (85,71%). Cinco casos apresentaram dois corpos estranhos, fragmentos da mesma natureza, em diversas localizações ou não; e três casos continham incontáveis fragmentos dispostos no segmento anterior. Considerando sua localização: córnea, 11 (26%); conjuntiva, 10 (23%); íris, 10 (23%); cristalino, 9 (21%); esclera, 5 (12%); seio camerular, 5 (12%); corpo ciliar, 3 (7%). Dentre as lesões associadas, identificou-se: perfuração corneana em 12 casos, laceração corneana em 2 casos, sinéquia anterior em 6 casos, aniridia traumática em 1 caso, iridotomia traumática em 3 casos, reação de câmara anterior em 10 casos e rotura de cápsula anterior do cristalino em 4 casos. Considerando a composição: metálicos, 21 (50%); não-metálicos, 20 de vidro (48%) e 1 de origem vegetal (2%). O tamanho dos corpos estranhos variou de 0,09 a 2,45 mm (média: 0,84 mm). CONCLUSÕES: A ultrassonografia biomicroscópica é útil para localizar corpos estranhos no segmento anterior. Este método de imagem pode proporcionar orientação sobre a natureza, o trajeto, a localização dos corpos estranhos e lesões associadas, facilitando o planejamento cirúrgico prévio à intervenção, evitando lesões adicionais ao olho.


INTRODUCTION: Ocular trauma is considered a health care problem because is an important cause for visual impairment. Intraocular foreign bodies are related to activities involving usage of metallic objects, but other materials can be present in the eye and have to be diagnosed and localized. Ultrasound biomicroscopy is an adequate subsidiary tool to evaluate an anterior chamber intraocular foreign body. PURPOSE: To characterize nature, localization, dimensions of foreign bodies and associated lesions to the anterior segment using ultrasound biomicroscopy. METHODS: Retrospective clinical study of 7,182 patient's charts submitted to ultrasound biomicroscopy examination between 1999 and 2008, totalizing 59 eyes suspected of anterior segment foreign body. RESULTS: Five cases presented two foreign bodies, fragments from the same nature, in different locations or not; and three cases had uncountable fragments in the anterior segment. Concerning localization: cornea, 11 (26%); conjunctiva, 10 (23%); iris, 10 (23%); lens, 9 (21%); sclera, 5 (12%); corneal angle, 5 (12%); ciliary body, 3 (7%). Among the associated lesions, it was identified: corneal perforation in 12 cases, corneal laceration in 2 cases, anterior synechia in 6 cases, traumatic aniridia 1 case, traumatic iridotomy in 3 cases, anterior chamber reaction in 10 cases and rupture of the anterior lens capsule in 4 cases. Considering composition: metallic, 21 (50%); non metallic, 20 were glass (48%) and 1 was vegetal (2%). The size of foreign bodies varied from 0.09 to 2.45 mm (average: 0.84 mm). CONCLUSIONS: Ultrasound biomicroscopy is useful to localize foreign bodies in the anterior segment. This imaging method can give orientation about composition, path, and localization of foreign bodies and associated lesions, thus facilitating therapeutic planning prior to intervention, avoiding additional lesions to the eye.


Assuntos
Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Segmento Anterior do Olho , Corpos Estranhos no Olho , Microscopia Acústica , Estudos Retrospectivos , Sensibilidade e Especificidade
5.
Arq. bras. oftalmol ; 69(3): 383-388, maio-jun. 2006. ilus, tab
Artigo em Português | LILACS | ID: lil-433803

RESUMO

OBJETIVO: Determinar a relação entre o comprimento dos processos ciliares com a duração, localização e gravidade das uveítes. MÉTODOS: Foram analisados em estudo prospectivo, 58 indivíduos, incluindo pacientes com diferentes estágios de uveíte e indivíduos sem a doença (112 olhos, sendo 18 normais), no período de agosto de 2001 a agosto de 2002, no Departamento de Uveítes do Cole Eye Institute da Cleveland Clinic Foundation - Ohio - EUA. Todos os pacientes foram referidos para o exame de biomicroscopia ultra-sônica, pelo Departamento de Uveítes após exame oftalmológico de rotina. O aparelho modelo 840 (Zeiss-Humphrey) com transdutor de 50 MHz foi utilizado para análise dos processos ciliares sob anestesia tópica e técnica de imersão. RESULTADOS: Em relação à etiologia das uveítes, a de maior freqüência foi a idiopática (27,8 por cento). As uveítes recorrentes, agressivas e difusas levaram ao significante dano nos processos ciliares. A maior perda significativa na medida dos processos ciliares foi encontrada no quadrante inferior e as maiores medidas foram encontradas em olhos normais e no quadrante temporal. CONCLUSÃO: A biomicroscopia ultra-sônica mostrou ser método útil para avaliar as alterações anatômicas encontradas nos processos ciliares dos pacientes com uveíte. De acordo com estes achados, podemos criar recomendações para futuros trabalhos, que nos ajudem a avaliar a necessidade destes pacientes vir a receber tratamento mais agressivo em qualquer sinal de inflamação, com o objetivo de prevenir futuro dano e eventual hipotonia.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Corpo Ciliar/ultraestrutura , Uveíte , Estudos de Casos e Controles , Doença Crônica , Microscopia Acústica , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores de Tempo